Bruker apex ii ccd detector burnt
Bruker apex ii ccd detector burnt





bruker apex ii ccd detector burnt
  1. Bruker apex ii ccd detector burnt generator#
  2. Bruker apex ii ccd detector burnt upgrade#

Stability of high-voltage and tube current with Saving of water using facility for connection to the internal cooling-water unit Minimized current consumption (patented circuitry) With side-window tubes and rotating anodes Use in diffractometers, film camera measuring stations,

bruker apex ii ccd detector burnt

Switch-off at tube flashovers (guarantees spectral purity)Ĭontrolled automatic increasing up to operational values after tube flashoversĭesign for installation in standard 19" racks

Bruker apex ii ccd detector burnt generator#

SMART, VIDEO, RLATT, GEMINI, SADABS, ASTRO/COSMO, SAINT+, FINDSYM, SHELXTL,įor all X-ray diffraction tubes and other side-window tubes:ġ00/80 mA current or 60 kV voltage with 3 kW output powerĬontrol via microprocessor and external PC or manual controlįLEX-CONTROL, the program for PC control of the generator as stand-alone device (e.g. PentiumTm-based PC with local mass storage, color SVGA display, and network communications Mo, normal focus 2400 watt or fine focus 2000 wattĬu, normal focus 2000 watt or fine focus 1500 watt Microprocessor controller with automatic startup and burn-in cycling for X-ray tubes Please refer to the text of the offer for the exact scope of delivery.Ġ.3, 0.5, 0.8 mm pinhole collimators, graphite crystal monochromator standard with sealed tube systems They do not represent the scope of delivery. The following illustrations and descriptions refer to the instrument model and are drawn from brochures. Bei Selbstabholung/EXW aus Drittländern und der EU werden 16% MWSt als Kaution einbehalten bis wir die Gelangensbestätigung/den Verbringungsnachweis des Käufers erhalten haben. Hinweis für Auslandssendungen: Ein Präferenznachweis/EUR1 wird von uns nicht ausgestellt. Falls anfallende Versandkosten nicht angegeben sind, fragen Sie diese bitte gesondert an.īei Lieferungen außerhalb der EU werden zusätzlich Gebühren im Wert von 70,00 € für die Ausfuhr berechnet. Angegebene Versandkosten sind zu erwarten. Unsere Lieferbedingungen sind grundsätzlich zzgl. Paketdienste, Speditionen, Selbstabholung, Lieferung durch Labexchange-Fuhrpark Auf ausdrücklichen Wunsch ist eine Teillieferung möglich. Die Versandzeit berechnet sich nach der Position mit der längsten Versandzeit. Die endgültigen Versandzeiten werden in der Auftragsbestätigung angegeben.īei Bestellung/Anfrage von mehreren Artikeln bieten wir grundsätzlich Sammellieferung an. Die tatsächlich Versandzeiten können im Einzelfall davon abweichen. Versandzeitĭie angegebenen Versandzeiten sind die jeweils kürzesten für einen Artikel. Sie erhalten voll funktionsfähige Geräte. You no longer need a liquid chiller, so mechanical stress is reduced.Status, Liefer- und Zahlungsbedingungen Geräteüberprüfungĭie gebrauchten Laborgräte werden vor der Auslieferung von der Labexchange Service GmbH überprüft. The new detector is completely air-cooled. Lysozyme diffraction image, demonstrating the high spatial resolution and sensitivity of the PHOTON II. This delivers the highest sensitivity and minimises parallax, giving you the performance necessary for weak intensities. The unique design of the PHOTON II 7 CPAD detector features an embedded scintillator, optimised for home laboratory wavelengths. Data is collected more efficiently – ideal for shared facilities and service crystallography labs. With a single monolithic sensor, there are no gaps or dead spaces between modules. Data collection is faster, with higher redundancy data for higher quality structures. This enables you to detect far more reflections in each frame. An even larger area is available with the PHOTON II 14 (10 cm x 14 cm). The PHOTON II 7 detector has an active area of 70 cm², which is almost twice the size of the previous APEX II. Shutterless mode enables you to acquire data faster, with a higher level of quality. This eliminates overhead time and mechanical jitter, which can be a problem with stop-start shuttered-mode operation.

bruker apex ii ccd detector burnt

Data is collected while the sample rotates continuously. Shutterless mode gives you better data, in a faster timeframe.

bruker apex ii ccd detector burnt

There are two models offering a choice of sizes.

Bruker apex ii ccd detector burnt upgrade#

We’re available to advise about upgrade compatiblity, so if you have any questions please get in touch.įor SMART APEX and KAPPA APEX owners, if you decide to upgrade later to a D8 QUEST or D8 VENTURE, the PHOTON II detector can be transferred to your new instrument, reducing the cost in future. The Bruker PHOTON II is available for these SC-XRD systems, both with new instruments and as an upgrade: 3D diffraction image of a transition metal complex (3 seconds exposure).







Bruker apex ii ccd detector burnt